Universal ECG™ Electrocardiogram ECG / EKG

Universal ECG™  Electrocardiogram ECG / EKG

The Universal ECG is the smallest and lightest 12 lead EKG on the market.



Turn an off-the-shelf PC or handheld into a 12 Channel EKG.

The Universal ECG is the smallest and lightest 12 lead EKG on the market.Perform resting ECG anytime, anywhere with unparalleled ease-of-use.

Additional benefits of the Universal ECG:

Print to any Windows® Printer

Edit Comments and Interpretation

Batteries Not Required

Patient Isolation and Defibrillator Protection (4000 Volts)

Create PDFs and JPEGs

Calibration and Maintenance Not Required

Connect via CF/PC Card Slot, Serial or USB port.

Included with each Universal ECG purchase:

- Universal ECG Cable - Narrative Interpretation
- Detailed Measurements
- USB Connector
- Snap/Tab Adapters
- Free Software
    Office Medic™ (Seven Languages)
    IDMS 5-user Network Software
    MedicSync™ Synchronization Software
    Pocket Medic™ Handheld Software.

Warranty : 3 years limited hardware warranty (1 year limited warranty on lead wires)

 

 

 

 

Hub Weight:

280 - 300 grams depending on cable options.

Hub Dimensions:

85 x 91 x 20 mm

Patient Leads Length:

1 meter

PC Connection Length:

1-3 meter, DB9 female connector

Patient Leads:

6 Lead Cable (4 patient leads) 12 Lead Cable (10 patient leads).

Case Material:

ABS plastic.

Electrode Connections:

4 mm banana plug with "tab" or "snap" connectors.

Electrode Labeling:

Abbreviations and colors to comply with either IEC or AAMI standards.

Display and Operating Console:

Dependent on PC (supplied by user).

Gain/Sensitivity:

5, 10, 20 mm/mV

Input Range:

±6mV

Acquisition Sample Rate:

1000 samples per second (compressed to 500Hz with peak picking and averaging algorithm).

Frequency Response:

0.05 to 175Hz ±3dB

Defibrillator Protection:

Patient leads are isolated from system and operator, with 4kV protection.

Common Mode Rejection:

-60dB (minimum)

Safety Standards:

Complies with AAMI EC11, EN60601-1, EN601-1-2, and EN601-2-25.

Leads Off Indicators:

Connection status for each lead is shown on Acquisition screen.

Power Source:

Can be powered by the PC Serial port control lines in most cases, depending on the PC being used. Can draw extra power if necessary from a PS/2 or USB port.

Supply Voltage:

4 – 16V DC

Supply Current:

<17mA DC

Permanent Filters:

High Pass: 0.05Hz 1st order

Low Pass: 170Hz 1st order

Baseline Wander: Baseline reset by adaptive zeroing algorithm.

Notch Filter (Mains Noise Rejection):

50Hz 4th order Butterworth,

49.1Hz - 50.9Hz,

60Hz 4th order Butterworth,

59.1Hz - 60.9Hz

Low pass (Muscle Artifact Filter)

35Hz 4th order.

Report Capabilities:

User selectable report formats.

Environmental Conditions:

Operating Temperature 0°C - 40°C
Storage Temperature -20°C - 70°C
Humidity 5% - 85% (non-condensing)

 